-40%

Dental X-Ray Unit Surgical Mobile Machine Sensor Handheld Digital BLX-5 (8Plus)

$ 279.83

Availability: 40 in stock
  • Brand: Unbranded
  • All returns accepted: Returns Accepted
  • Country/Region of Manufacture: China
  • MPN: XG1170100101
  • Item must be returned within: 30 Days
  • Condition: New
  • Restocking Fee: No
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Return shipping will be paid by: Buyer
  • Model: BLX-5
  • Custom Bundle: No
  • Intended Use/Discipline: Dentistry
  • Modified Item: No

    Description

    Description:
    BLX-8Plus
    Product introduction:
    This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays).Using a Toshiba 0.3 micro-focus tube.The tube voltage frequency of this machine is 30 KHz,and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees, located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
    TECHNICAL SPECIFICATIONS:
    Tube Voltage
    65kv
    Tube Current
    1mA
    Time Exposure
    0.1~~1.8s
    High pressure generator
    30kHz DC
    Rated Power
    60w
    Focal Spot To Skin Distance
    >20CM
    Focus Spot Size
    0.3mm(TOSHIBA)
    Charger Input Voltage
    AC110V~220V
    Supply Frequency
    30Hz
    Radiation Leakage
    <20ugy/h
    Battery
    24V DC 2600MA
    Weight
    4.3KG
    Dimensions
    37 cm×31 cm×28cm (L×W×H)
    Reference of the Angles :
    '
    Tooth
    Upper
    Lower
    1-2
    42
    -15
    3
    45
    -18
    4-5
    30
    -10
    6-8
    28
    -5
    Reference of the time of exposure:
    Tooth
    Adult
    Child
    Central & Lateral
    0.2-0.3
    s
    0.2-0.3
    s
    Cuspid & 1st Bicuspid
    0.3-0.4
    s
    0.3-0.4
    s
    Upper 5,6
    0.5-0.6
    s
    0.5-0.6
    s
    Upper 7,8
    1.3-1.8
    s
    1.2-1.5.
    s
    Lower 5,6
    0.5-0.6
    s
    0.4-0.5
    s
    Lower 7,8
    0.6-0.8
    s
    0.5-0.7
    s
    Packing List:
    Main machine   1pcs
    Power line      1pcs
    User manual     1pcs
    ++
    BLX-5
    Features:
    1.) The tube voltage frequency of this machine is 30 KHz, and the tube current is 0.2 MA. The radiation scope is at an angle of 24 degrees, located within a distance of 1.2 meters ahead.
    2.) Toshiba 0.3mm x 0.3mm micro-focus tube
    3.) No protective operation room is needed when installing the complete machine
    4.) Flexible adjustment of position and angle of handpiece
    5.) Compact in volume, light in weight, convenient for carrying
    6.) Time is adjustable, high contrast of picture, imaging in focus
    7.) There are vacuum components and high-pressure parts inside of the machine, so for your safety and the maintenance of the machine
    8.) The tube head is equipped with excellent radiation-shield protection (except the radial mouth, and tests have shown that the radial index is zero. Safety is guaranteed.
    9.) Non-film inspection and storage can be realized when corresponding to a sensor
    Specifications
    Voltage: 110v±10%
    Power: 24V 8000MA
    Charger: 110V, 50Hz
    Tube current: 0.1mA
    Rating: 60W
    Frequency: 30 KHz
    Exposure time: 1-9 seconds optional
    Leak radiation: < 20μgy/h(12lb)
    Focus Skin Distance: >20cm
    Tube voltage: 60KV
    Relative Humidity(RH) < 80%
    Storage conditions: 5-40 degrees Celsius, relative Humidity
    Net weight: 5.5 kg
    Dimension: 47 x 42 x 19 cm
    Content:
    Main Unit x 1
    Dental Film Position x 1
    Charger x 1
    English Manual x 1
    Warranty Card x 1
    Operation of the Main Unit
    1. Upon receiving, open the box and check the product for possible damage during shipping.
    2. Make sure the fittings on the encasement list are packaged within the box.
    3. Connect the six-core cable (of the Main Unit) to the joint of the ball head and tighten the screw
    4. After the Main Unit and ball head are perfectly fit together, plug in the international standard electrical source, grounding is strongly recommended.
    5. Turn on the Power; the pilot lamp will be light up.During this time, the digital tube of the main unit will show the fore setting time. Now the equipment is in standby mode.
    6. Setting the time (Skip to next step if unneeded) Use the "SET", "+", and" -" buttons to reset the time as follows: press SET, the pilot lamp above is illuminated, the machine is now in the time setting mode→then press "+" and" -" to set the time needed (time range is 0.5-9seconds); press set again when the time is adjusted the light lamp is off. The equipment is now in standby mode.
    7. Put the Tooth film plumb behind the tooth which is going to be taken picture, and be as close as possible (the smooth side stick to the tooth)
    8. Keep the ball head plumb to the tooth projection position; Have the ball head, tooth, and tooth film steadily mutually plumb.
    9. After positioning, use theEXP on the main Unit, the remote controller, or the button on the touch head tube to take pictures. The three methods have the same effect. (Notice: gently press)10. After exposure to the tube, release the start button again (available in three ways) in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray, so the dental films can be used again).Repeat step 6 to reset the picturing time.To repeat the picturing process, please repeat steps 7 to 9.
    11. Turn the power of the main unit off when the work is finished, press POWER, making sure the pilot lamp is off. Don't keep the main unit long in standby mode.
    Points for Attention
    1.
    Make sure the angle of film, tooth, and b
    all head are properly aligned when taking a picture. Keep them steady until the last step of picturing; making sure that there is no change in any of their positions.
    2.
    Remember to turn the power offwhen work is done.
    3.
    Change the battery if the remote controller loses its functioning or if the remote's distance is shorted.
    4.
    After turning the power on, wait one minute before taking pictures, this allows the ray to provide a steady output.
    5.
    The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs, it will not be able to carry out the normal work of filming.
    6.
    When taking pictures, the EXP button could stop the objection and then the machine goes back to the preparation mode.
    7.
    Use high quality tooth film and developing liquid to make clear pictures.
    8. Handle the ball head gently while in use, so as not to damage the delicate component.
    9.
    Do not pull hard on the cable which connects the ball head to the main unit.
    10.
    The cable connecting the ball head to the main unit cannot bear the weight of the ball head, so do not raise the ball head by holding the cable, it will cause damage.
    11.
    We usually set the time between 3-8 seconds when taking pictures, but the actual time of ray output is 0.2-0.5 seconds.
    12.
    If a situation occurs, preventing the machine from taking regular pictures, contact the seller to solve the problem instead of trying to service the product yourself.
    13.
    Keep the tooth film and the liquid in a proper place and use them within the shelf-life period. While, because the liquid is not allowed to ship by carrier normal, so we take it out before ship, look forward to your understanding.
    14.
    Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.
    15.
    Other requests accordance with the scope of the technical parameters.
    16.
    Please read the manual carefully before using.
    Notes:
    Due to the electrification inspection of the customs ,in the recent the X-ray will send you without the battery, please understand!
    Seller name: BAISTRAWORLD
    City,State: SHENZHEN. CHINA
    Telephone number:0755-62289361
    FDA Statement:
    The sale of this item may be subject to regulation by the U.S. Food
    and Drug Administration and state and local regulatory agencies.
    So you can bid it on this item only if you are an authorized purchaser.
    If the item is subject to FDA regulation,We have to verify your status
    as an authorized purchaser of this item before shipping of the item.
    Thanks for your understanding!
    Exchanges are offered for items that are defective or damaged when received, although this is highly unlikely. After exchanges are made and              have not resolved the issue, we will refund the cost of the merchandise.
    Defective items or problems with your order must be reported within 3 days after receiving. Please keep all packaging, documentation, packing              list,etc. that came with your order. These will be used to verify claims if there is any problem with you.
    Restocking fee will be charged for returned items without original package or any quality problem.Please contact us for details before              returning your package to avoid misunderstanding.
    IMPORTANT: Customer's item must be returned to our facility with the ROF (Return Order Form) at the buyers shipping expense.
    The goods you odered will be posted out in the second working day after the paymet has been made. (We will inform you via email if any delay occured due to holiday events.
    General shipping time is between 7-12 working days. (After the shipping started, the order will be monitored and the track of the item will be posted on paypal.
    We accept PayPal only.
    The address in your paypal details will be used as the actual shipping adress, please make sure the adress is correct.
    If you are planning on combining your items, please make sure that you wait until ALL auctions have ended before you visit the checkout. All items must be paid within 7 days.
    Serivce is our 1st priority at Baistra!
    If you contact us immediately after placing the order, we will make every effort to assist you with your change request. Unfortunately, we can not make changes or cancel an order once it has shipped.
    We offer the best items at the best prices. We strive to exceed all your expectations and put a smile on your face. Your experience will be a pleasant and effortless one when you buy at Baistra. We stand behind our products and pride ourselves on OUTSTANDING customer service. We guarantee that you will be delighted with your purchase or we will gladly and promptly issue you a refund or make things right!